netviz GitHub

netviz impact

netviz impact answers the question an inventory exists to answer and a diagram cannot: what breaks if this dies. It removes elements from the resolved graph, derives every layer again without them, and reports what stops being reachable — or, given nothing to remove, enumerates the single points of failure that were there all along, ranked by how much each one would cost.

Nothing is pinged and no device is contacted. The answer is what your documentation says would happen, which is exactly the thing to compare against what does.


Contents


Synopsis

netviz [GLOBAL OPTIONS] impact [OPTIONS]

Naming what fails

--fail takes four spellings, tried in this order so no later one can shadow an earlier:

A name that matches nothing, or several things, is a usage error that lists what it could have meant instead:

$ netviz impact --fail sw-01
Error: Invalid value for '--fail': 'sw-01' is ambiguous: it matches 3 elements.
Qualify it with a namespace or a kind, e.g. 'device/sw-01'.

--fail is repeatable, and several failures are simulated together — a maintenance window that takes out a switch and re-patches a rack is one event, and analysing the two separately would miss exactly the case where each is survivable and the pair is not.

Where reachability is measured from

"Unreachable" needs a from. By default that is the designated gateways: the elements holding an address that some other interface names as its gateway. That is the one definition the files already carry, and it is the right one — a router nobody points a default route at is not what anybody loses service through.

Failing that, in order: the elements of kind router, with the report saying so; and if the inventory has neither, reachability is not measured at all and only the partitions are reported. --from overrides all of it and takes the same spellings as --fail.

--fail: the blast radius

$ netviz impact --fail device/sw-north-acc-01 --layer l1
1 element removed:
  sw-north-acc-01 (switch)

reachable from 1 gateway: sw-north-dist-01

l1 (physical): 19 of 22 elements still reachable
  2 elements isolated:
    sites/north/hosts/pc-north-01
    sites/north/hosts/srv-north-01
  sites/north/hosts is now in 3 pieces, was 1:
    1. pc-north-01
    2. srv-north-01
    3. pc-north-02

summary: 2 isolated at worst

Three things are reported per layer, and each answers a different question.

Isolated is the direct answer: elements that could reach a gateway and now cannot. A failed element is never in this list — it is gone, not stranded — and neither is anything that was already unreachable before, which is counted separately so a pre-existing island is not mistaken for new damage.

Partitioned namespaces answer the question the count does not. "The inventory is in four pieces" is not actionable; "sites/north is in two" is, because a namespace is a site, a floor or a rack, and a site split in half is an outage with an address.

The layers disagree on purpose. Layer 1 is the plant, layer 2 the broadcast domains, layer 3 the routed adjacency, and a failure that halves a VLAN without partitioning the cabling is a real and different thing from one that cuts a cable. The layers are derived again from the pruned inventory rather than patched — a broadcast domain is found by walking the links that carry a VLAN, so deleting a cable from a finished layer-2 graph would leave the domains it split none the wiser.

Power failures cascade

src/netviz/power.py already resolves every feed, so a PDU is not a special case in the topology — it is a source, and everything whose only remaining source is gone goes with it, transitively:

$ netviz impact --fail pdu/pdu-a --from rtr-core
1 element removed:
  pdu-a (pdu)

2 elements lost power as a consequence:
  sw-poe (switch, lost pdu-a)
  ap-1 (computer, lost sw-poe)

The cause named is the source that actually went dark — the switch above the access point, not the PDU two steps up — because an operator restoring service works up the chain from what they can see.

A device with two cords into two PDUs survives either. A device with two cords into one survives neither, and that is what E042 and --spof are for.

--path: assertions that survive, or do not

--path SRC=DST re-runs the trace engine on both sides of the failure and reports whether the route survived. Each end takes the spellings netviz path takes; = separates them, because a colon already means element:interface and an arrow has to be quoted in every shell there is.

$ netviz impact --fail sw-north-acc-01 --path pc-north-01=srv-north-01
paths:
  broken    pc-north-01 → srv-north-01  (1 route the trace still finds crosses a
            prefix or a tunnel whose two ends are no longer physically connected,
            so it is not counted)

That note is the one correction this command makes to the trace engine, and it is worth understanding. The layer-3 search calls two elements adjacent when they hold addresses in one prefix — the right definition for a route, and not a sufficient one for a frame. Unplug the switch between two hosts in 10.1.10.0/24 and they are still in that prefix. So every route is checked twice over: once by the trace engine, once against the physical graph, and a route whose hops are not physically realisable is not counted as surviving. Reporting one as intact is the most dangerous thing this command could get wrong.

A status is one of unchanged, degraded (fewer routes than before, at least one left), broken (none left) or missing (there was no route even before, so this says nothing about the failure).

--spof: single points of failure

With no --fail, impact enumerates instead of simulating. Every articulation point and every bridge of every requested layer, ranked by how many endpoints each one isolates:

$ netviz impact --spof --limit 5
reachable from 1 gateway: sw-north-dist-01

38 single points of failure, worst 5 shown:
  isolates  layer  what
        21  l1     sw-north-dist-01 (switch, articulation point)
        21  l3     sw-north-dist-01 (switch, articulation point)
        15  l1     cbl-north-core-dist (cable, bridge)
        14  l1     rtr-north-core-01 (router, articulation point)
        14  l3     rtr-north-core-01 (router, articulation point)

Four things about that list.

One of a redundant pair is not a bridge. Two cables in a LAG join the same pair of switches; cutting one leaves the other, and neither is reported.

An anchor can be a single point of failure without being an articulation point. Lose the only gateway and everything downstream is cut off from the network even though the graph never split. The ranking is therefore computed for every element rather than only for the cut vertices — sole anchor is what the report calls this case.

A VLAN is not a thing you can unplug. Layer 2 and layer 3 have nodes standing for broadcast domains and for IP prefixes, and both are cut vertices of a real graph. Neither is reported: an item on a maintenance plan that no engineer can act on is worse than no item.

Power is swept separately. A device whose cabling is textbook redundant and whose two supplies are both in one PDU has a single point of failure that no amount of graph theory over the cables will find. A PDU feeding a switch that sources PoE for six access points is reported as isolating all seven.

--limit is the cutoff for large inventories — a thousand-device tree has more than a thousand single points of failure, and answering a question with a thousand rows is not answering it. The report always says how many there were in total, so a truncated list never reads as the whole answer. --min-isolated raises the floor: --min-isolated 5 asks only about the failures that would cost five endpoints or more.

--redundancy: promises the files make

An inventory records what the network is. An annotation records what it is for:

metadata:
  name: sw-ward-01
  annotations:
    netviz/redundancy: "gateway, power"

gateway says losing any one element must not cut this one off from its default gateway. power says losing any one power source must not switch it off. Both are design intent, both are the kind of intent that quietly stops being true when somebody re-patches a rack, and both are graded by ordinary validation rules — E047, E048 and W141.

Ordinary means netviz validate gates on them too, which is the point: CI fails the change that removed somebody's second path, and netviz impact --redundancy is where you go to find out why.

$ netviz impact --redundancy
1 redundancy expectation not met:
  E047 element 'sites/north/hosts/pc-north-01' declares a 'gateway' redundancy
  expectation, but 3 single failures would cut it off from its gateway 10.1.10.1
  on 'sites/north/distribution/sw-north-dist-01': sites/north/access/sw-north-acc-01,
  cable sites/north/cables/cbl-north-dist-acc01, cable
  sites/north/cables/cbl-north-acc01-pc01. Add a second path, or drop the expectation.

-F sarif and -F github are accepted with --redundancy only, and carry the findings alone. Both describe problems in files, and "losing sw-core-01 strands 43 hosts" is not a problem in a file — it is a property of a network that no line of YAML is guilty of. See docs/ci.md for the upload.

Failure mode in the editor

netviz web DIR has the same analysis on the canvas. Alt-F puts the session in failure mode; clicking an element greys out everything its loss would isolate and the status line names the count. Escape or Alt-F again puts the diagram back.

It is read-only from end to end. The route behind it builds a throwaway inventory and writes nothing — no file, no revision, no undo entry — which is why leaving the mode is instant and why it is available in a read-only session.

Output for a program

-F json is the whole analysis: every layer, every isolated element by name, every partition with its fragments, every checked path, and the ranked single points of failure with total and reported beside them so a truncated list is never mistaken for a complete one.

{
  "schemaVersion": 1,
  "tool": { "name": "netviz", "version": "0.0.3" },
  "modes": ["fail"],
  "anchors": { "elements": ["sites/north/distribution/sw-north-dist-01"], "source": "gateways" },
  "failed": [{ "element": "sites/north/access/sw-north-acc-01", "kind": "switch",
               "cause": "requested", "spec": "device/sw-north-acc-01" }],
  "layers": [{ "layer": "l1", "served": { "before": 22, "after": 19 },
               "isolated": ["sites/north/hosts/pc-north-01"], "partitioned": [] }],
  "summary": { "isolated": 2, "brokenPaths": 0, "violations": 0, "impacted": true }
}

Keys are only ever added, never renamed; schemaVersion is bumped only for a change that could break a consumer. Ordering is fixed everywhere: two runs over an unchanged tree produce byte-identical output, so a report can be committed, diffed and reviewed.

What this does not model

Being explicit about this is the difference between a tool that is trusted and one that is believed.

Performance

Measured by tools/bench_impact.py on the 1056-device tree tools/bench_pipeline.py generates — 2106 documents in 138 files, 1.2 MB of YAML. A generated tree is the worst case for --spof: a tree has no redundancy at all, so every internal node is an articulation point and every cable is a bridge.

Stage Time What it is
load_tree 493 ms Parsing the tree. The floor under every command.
derive anchors 1.3 ms One scan of every interface for a declared gateway.
build views (l1, l2, l3) 247 ms One resolution pass plus the broadcast-domain walk.
--fail (one element) 606 ms The whole simulation: both sets of views, and the prune between them.
--spof (three layers + power) 300 ms 1104 single points of failure found and ranked; the worst 25 named.
analyse() on layer 1 alone 5.7 ms Every articulation point, every bridge and every isolation count, in one pass.
--redundancy 112 ms The validation pass, with an expectation on all 42 rack switches.

Median of five runs, Python 3.12, libyaml. Two of those numbers are the design.

analyse() at 5.7 ms for 1056 nodes is what makes --spof usable at all. The obvious implementation — remove each candidate, re-traverse — is O(V·(V+E)), which on this tree is a few million node visits per layer and takes minutes. netviz.connectivity gets every articulation point, every bridge and every isolation count out of one depth-first search, from the subtree sizes and the number of anchors each subtree contains. The identities of the isolated endpoints are materialised only for the entries the report prints, which is the other thing --limit is for.

--fail at 2.5× the cost of building the views once is the price of exactness, and it is deliberate: the second pass re-derives the layers from the pruned inventory rather than patching the first, which is the only way the broadcast domains and the routed adjacency come out right. It is affordable because a --fail run does it twice in total rather than once per candidate.

Options

Flag Value Default Meaning
--fail ELEMENT Remove this element and report what breaks. Takes a name, a fully-qualified name, or a kind-qualified one such as 'device/sw1' or 'cable/rack1-a3'. Repeatable: several failures are simulated together.
--from ELEMENT Measure reachability from here instead of from the designated gateways. Repeatable.
--path SRC=DST Re-run this trace on both sides of the failure and report whether it survived. Repeatable. Each end takes the spellings 'netviz path' takes.
--spof off Enumerate the single points of failure instead of simulating one, ranked by how many endpoints each isolates. The default when no --fail is given.
--redundancy off Check the redundancy expectations elements declare in their 'netviz/redundancy' annotation, and report E047, E048 and W141 through the ordinary rule machinery.
--layer [l1|l2|l3] Which views to analyse. Repeatable; all three by default.
--limit N 25 Report at most this many single points of failure. 0 reports every one of them.
--min-isolated N 1 Ignore a single point of failure that isolates fewer endpoints than this.
-F, --output-format [text|json|sarif|github] text text is the report; json is the whole analysis for tooling. sarif and github carry the --redundancy findings alone, for a code-scanning upload.
--fail-on [impact|none] impact Exit 1 when something was isolated, a checked path broke or a declared expectation was not met, or never. Enumerating single points of failure never fails the run.
--strict off Treat warnings as errors.
--force off Proceed even when validation failed. The result may not match the files.

Exit codes

Code Meaning
0 The analysis ran. Nothing was isolated, no checked path broke, and every declared expectation was met — or --fail-on none was given.
1 A simulated failure isolated something, a checked path broke, or an expectation was not met. Also: the inventory was rejected and --force was not given.
2 Usage error: --fail, --from or --path names nothing or names too much, or -F sarif was asked for without --redundancy.
3 The inventory could not be discovered or read at all.
130 Interrupted.
141 The downstream end of a pipe closed first.

Enumerating single points of failure never fails the run. Every network of any size has them, and a command that exited non-zero for saying so is a command nobody could put in a pipeline.